|
October
1999
Issue #3
Cattle Implants
By
Jason Meuller Contributing Authors: Bytor and Animal
This information
in this article is not presented as medical advice. No one reading
this article should assume that the printing of the article is an
endorsement of the activities it describes. This article is for
entertainment purposes only and is not intended as a plan of action,
recommendation, or promotion of any activity.
Cattle implants
contain a variety of growth promoting hormones. For our purposes,
the only implants that are of interest contain either trenbolone
acetate or testosterone. Listed below are the implants available
in the United States that meet these criteria:
|
Implants
Containing Trenbolone
|
|

Revalor-G
Each
cartridge contains 10 implants
Each implant contains:
8 mg estradiol benzoate
40 mg trenbolone acetate
Revalor-S
Each
cartridge contains 10 implants
Each implant contains:
24 mg estradiol benzoate
120 mg trenbolone acetate
Finaplix-S
Each
cartridge contains 10 implants.
Each implant contains:
140 mg trenbolone acetate
Revalor-H
Each
cartridge contains 10 implants.
Each implant contains:
14 mg estradiol benzoate
140 mg trenbolone acetate

Finaplix-H
Each
cartridge contains 10 implants.
Each implant contains:
200 mg trenbolone acetate

Synovex
Plus
Each
cartridge contains 10 implants.
Each implant contains:
28 mg of estradiol benzoate
200 mg trenbolone acetate
|
|
Implants
Containing Testosterone
|
|

Synovex-H
Each
cartridge contains 10 implants.
Each implant contains:
20 mg estradiol benzoate
200 mg testosterone propionate

Implus-H
Each
cartridge contains 20 implants.
Each implant contains:
20 mg estradiol benzoate
200 mg testosterone propionate
|
Before we begin,
please notice that most of the above implants contain estradiol
benzoate. Using any of the above implants without removing the estrogen
component first will result in a variety of unpleasant side effects.
With the ever-decreasing
availability of real anabolic steroids, many athletes are turning
to more exotic and esoteric means of obtaining the drugs they need
to compete in their chosen sport. For some, this has meant turning
to the use of cattle implants. This article will fully explore the
use of cattle implants for performance enhancement by examining
the various implants, methods of application, and steps for breaking
these implants down into injectable substances. There are two basic
methods of application athletes use to utilize the hormones found
in these implants. The first method involves the use of dimethyl
sulfoxide or DMSO. DMSO is a natural solvent derived from wood pulp.
It acts as a transdermal carrier, and when mixed with the ground
up pellets of these implants, will actually carry the hormones through
the skin and into the bloodstream. However, this method has several
drawbacks. Toxicity becomes an issue as DMSO will carry any substance
below a given molecular weight through the skin and into the blood.
This can include some of the binders and glues found in the implant.
Additionally, DMSO can be very irritating to the skin and causes
the individual using it to release a very strong odor from both
their breath and skin. DMSO can be found on the Internet at www.dmso.com
or www.dmso.net. Although DMSO should not be used on humans, anyone
planning on doing so must not use the industrial grade! Be sure
any DMSO you buy is of 99.9% purity.
Athletes choosing
the DMSO route of administration will usually apply it on a daily
basis due to its rapid clearance from the body when applied via
this method. Dosages vary, although 60 mg per day seems to be very
effective for most.
Athletes planning
to use cattle implants via the DMSA method should be aware of the
following:
1.The pellets
must be very finely ground for this method to work effectively.
Don't simply crush a few pellets with a spoon and think the DMSO
will magically leech the hormones out from the large particulates.
2.The DMSO
should be mixed with water at a 1/1 ratio. For those of you that
aren't mathematically inclined, this would give us a solution
of 50% DMSO and 50% water. Be sure to use 99.9% pure DMSO!
3.Use as little
of the DMSO/water mixture as possible to apply the finely ground
up powder. Using more than is necessary will not make the absorption
of hormone more efficient and creates a huge mess.
4.Remember
that DMSO is a transdermal agent and will carry most substances
directly into your blood! This requires that the area of skin
used for application is thoroughly cleaned before applying the
DMSO/water/hormone mixture. The area should be washed with a non-perfumed
soap and then washed again under hot water to completely remove
any residue from the soap.
5.After applying
the mixture to the skin, it's important to let it dry completely
before putting any garment on top of the area of application.
Remember, not only is DMSO a transdermal carrier, but it also
acts as a solvent. Any substance with a small enough molecular
weight will be carried into your body by the DMSO which can include
substances on and in your clothes like detergents and dyes. Some
athletes will apply plastic wrap around the area of application
to ensure that no foreign matter is carried into the body.
The second method
of administering these hormones requires that the implants are broken
down into an injectable substance. Out of desperation, some athletes
simply crush the pellets and mix them with whatever sterile oil
or water they have handy. While this certainly will get the desired
hormone into the body, it's very risky as the resulting compound
is not sterile and contains all of the binders and glues found in
each pellet.
Many athletes
utilize a slightly more complex method of formulating an injectable
that solves the problems created by simply mixing the crushed pellets
in the method described above. By mixing the crushed pellets with
propylene glycol, benzyl alcohol, and polyethylene glycol, it's
possible to create a much more effective injectable that is resistant
to microbial contamination.
The following
materials are required to complete this experiment:
-trenbolone
acetate
-propylene
glycol
-benzyl
alcohol
-polyethylene
glycol
-syringe
filters
The polyethylene
glycol (PEG), propylene glycol (PPG), and benzyl alcohol (BA) should
comprise 60, 30, and 10% of the final mixture respectively. Therefore,
if it was your intention of producing 100 ml of injectable, you
would need 60 ml of PEG, 30 ml of PPG, and 10 ml of BA. For 50 ml,
you would use 30, 15, and 5. The final concentration of trenbolone
in your injectable is determined by how dividing the total mg of
amount of trenbolone by the total ml volume of the solution. For
example, if you desired to make 50 ml of injectable with a final
concentration of 50mg/ml, you would need to start with 2500 mg of
the steroid.
The procedure
is as follows:
1.The required
amounts of PPG and BA should be mixed together.
2.The required
amount of steroid should be added to the solution while it is
heated. It's best to immerse a sterile container containing the
solution and pellets into hot water so that the temperature can
of the mixture can be carefully controlled. Care should be taken
not to allow the solution to become too hot.
3.After the
steroid has dissolved completely into the PPG/BA solution, add
the PEG and mix the solution until it is evenly distributed.
4. Draw the
solution up in a syringe and pass is through the syringe filter
into a sterile container. This will remove any particulates that
may be present and help sterilize the solution.
5.As an optional
step, some athletes will initially dissolve the pellets in acetone.
The resultant solution is then poured through several coffee filter,
catching the glues and binders. The end solution should be left
to evaporate until you are left with pure trenbolone crystals.
The third and
final method of producing an injectable is to purchase an experimental
kit designed for that purpose. The advantages of purchasing a kit
is that all of the materials necessary for the experiment are provided
for you at very little expense. One very popular kit is profiled
later in this article.
Removing
Estradiol Benzoate from Testosterone Implants
Any athlete
who uses an implant containing estradiol will rapidly find themselves
shopping for comfortable bras. No amount of anti-estrogen can block
the effects of the large amount of female hormone contained within
these implants. The only way to effectively use these implants is
to remove the estradiol component prior to administration.
So, how can
the estradiol benzoate (EB) be separated from the testosterone propionate
(TP)? By examining the Merck Index, it's clear that while TP is
readily soluble in ether, EB is not. Various kits are available
that take advantage of the different properties of TP and EB. Using
one of these kits are a must before using either Synovex or Implus-H.
These kits will not remove 100% of the estrogen contained within
the implant so concomitant use of an estrogen blocker is required.
The
Interview with Animal
For those of
you unfamiliar with the individual who refers to himself as "Animal"
we thought this would be a great opportunity to introduce you to
one of the more creative minds in bodybuilding. Animal is somewhat
of an authority on cattle implants, providing kits to turn the pellets
into a sterile injectable solution. Of course, these are designed
simply to make these pellets for effective for use in animals, and
are not designed for human use. We contacted Animal and he contributed
the following brief interview.
AE: So, what
initially inspired you to create a kit that would convert an implant
to an injectable?
Animal:
I didn't like using DMSO and my wife didn't like me using it either!
Being a chemist with a challenge and seeing that many wanted an
injectable because they didn't like DMSO was also the motive. And
of course, I saw there was a market which nobody had exploited for
money. Not that I saw it as a way to become a millionaire, but a
way to get a few extra bucks and allow me to write and do other
experiments which the athletic community could benefit from.
AE: What do
you feel are the advantages of administering these hormones through
injection vs. an implant?
Animal:
When compared to the DMSO transdermal method you can use 1/2 or
less of the injectable. DMSO use dictated the application of 150-200
mg EOD. Feedback is indicating that injected solutions give more
muscular and less marbled animals. (Your animals are going to be
leaner.) However, the most important benefit is that there is no
STINK or skin rash from the DMSO. Another
problem that we have to realize with DMSO is how fast it gets to
the bloodstream. DMSO gets ALL of your dose into the blood very
rapidly. It gets into your blood and then it's gone, much like an
oral D-bol or androstenedione dose. The presence of AS spikes way
up within an hour and then it's gone. Therefore, if you wanted to
have a constant supply of tren in the blood you would need to apply
DMSO 3-4 times a day. The oil gives you a more consistent and longer
lasting level of trenbolone in the blood.
AE: Have you
had any feedback from ranchers using trenbolone acetate in their
cattle? What kind of increased growth are they seeing?
Animal:
Most are reporting 5-15 lbs of lean mass over their cycle which
could be in the range of 4-12 weeks. I don't believe in those 2
and 3 week cycles. They also report a very good increase in strength
which starts increasing around 4 weeks. Nevertheless, the most noticeable
qualities are increased vascularity and hardness.
AE: I know many
of our reader enjoy experimenting with chemistry. What yield should
they shoot for when attempting to isolate testosterone from say,
a Synovex implant?
Animal:
I get around 90% yield, but since most don't weigh the end product,
I formulate for 80%. This is still 16,000 mg from 20,000 mg of Synovex.
[Editors note: One cartridge of Synovex contains 2000 mg of testosterone
propionate. When he refers to 20,000 mg, he is referring to the
testosterone contained in a box of 10 cartridges, 100 actual implants.]
AE: How effective
are your kits at removing estradiol?
Animal:
The ether method will work, but is difficult to do and you could
still get estradiol in your final product if not careful. The only
other way is to remove the esters off all the AS, then use the solubility
properties of the estradiol benzoate (Eb) to remove it from the
testosterone propionate (Tp). Sorry if I'm not more specific, but
I'm the only one I know that actually knows how to do this!
AE: I know that
many ranchers are concerned with the sterility of these products,
not wanting their cattle to get abscesses and such. Realistically,
how sterile are these products once converted?
Animal:
The syringe filters are to thank for the sterility. 0.45 micron
syringe filters stop all bacteria so sterility is not really a problem.
I have a good rapport with my customers and I have never heard on
one infection from using those filters in over 2 years and over
that time I have sold 5,000 syringe filters for various purposes.
Editors
Note: Animal sells a variety of items that can be helpful to
all of you potential ranchers out there. With his permission, his
email address is listed here. Happy ranching!
animal@skuz.net
The
Famous Bytor Post
We should all
thank Bytor for his excellent step-by-step instructions on how to
break down the finaplix cartridges. With Bytor's permission, we've
reprinted his post in its entirety.
Here is what
you should have to convert 1 cart of Finaplix -h to an liquid for
injecting. One cart will create approximately 22-24cc's of 75mg/cc
Trenbolone.
Items include:
-Vial 1 containing
the magic dissolving liquid
-Vial 2 containing the oil based liquid
-Vial 3 is a sterile vial
-20 ml sterile syringe
-Sterile fine filter (upper right of pic)--(All there is now is
a 0.45 micron Glass GD/X filter, no coarse filters needed)
-2 coarse filters (look like push up tops)--no longer supplied
in kit because they are not needed
-2 18g needles
-1 cart of finaplix -h (sold separately) (you could put in that
this will do 2000mg of any hormone such as androstendione or norandrostenedione
as well.)

1.Take metal
cap off of vial 1, remove rubber cap and insert pellets into vial.
Let it sit like this overnight. The pellets will begin to dissolve.
The next morning, take vial 1 and swirl it to mix the contents,
and let it sit again the rest of the day. I have found that you
can totally dissolve the pellets in this manner without using
the heating process. It you want to speed things up you can use
the heating process
.

2.(if required):
If the heating process is required for your situation, boil some
water on the stove in a pot. Once boiling take the pot off of
the hot stove eye. Place the vial in the water as shown below,
and let the water warm the mixture for a minute or so and then
take it out and swirl it. Repeat until all pellets are dissolved.
WARNING: do not let the mixture get too hot, it will start to
turn brown and the glue/binders will clog your filters later in
the process.

3.Take vial
2 and put its contents into vial 1. This is adding the oil to
the solution. Once added, swirl the contents and let it sit overnight
(or an equivalent amount of time).

4.Take the
20ml syringe and place the 18g needle on it and draw up the "translucent"
part of the separated solution in vial 1. Do your best not to
draw any of the yellow glue and binders. To get the last little
bit you can turn the vial to its side and draw up a couple of
extra cc's. Also: The remaining solution has a lot of Tren left
( About two weeks worth...let it sit a few more days and you can
draw up more solution. A few binders wont hurt you and you will
get about 5ml more.

5.After drawing
the translucent mixture, place the course filter over the end
of the syringe and filter the solution into vial 2. You will notice
the solution gets clearer. You have 2 coarse filters in case the
first one clogs.

....separation
of the glue/binders is complete.

6.To further
filter out any left over particles. Draw the solution in vial
2 up with the second needle

7.Then, using
the sterile fine filter (being careful not to contaminate it),
filter the contents into vial 3.

THIS
IS YOUR FINAL PRODUCT: 22-24ml of 75mg Trenbolone!!!

Hope this helps!
Bytor
Addendum:
Animal's detailed instructions.....
Read the directions
first and 'variations' section! The steps are designed to get it
done fast and be 'almost' idiot proof.
What you should
have in your 'Sterile' kit:
-A sealed
clear vial with 4-8ml magic solution marked '1'.
-A sealed clear vial with oil in it marked '2'.
-A sealed clear or amber, sterile, vial marked '3'.
-Two 18 gauge 1.5 inch needles.
-One 20ml syringe. This is the largest syringe we can use with
the sterile filters.
-1 clear, sterile, 0.45um GMF sterile syringe filter.
-A real cheap coffee filter.
What you should
have in an 'EZ' kit:
-A large
sealed, clear vial marked '1' with 3-5ml magic solution.
-A large clear sterile vial marked '2' with oil in it.
Note:
In the following steps, the term 'hormone' can mean any AS type
structure including, but not limited to, androstenedione, norandrostenedione
and other 'pro-hormones'. It can also mean outright steroids in
countries where they are legal. Please do not do anything illegal
with the kits.
How to keep
a bottle sterile:
1.Tear out
the aluminum center circle of the amber bottle.
2.Tear off the rest of the aluminum.
3.Using syringe filters or sterile contents from the clear bottle
inject back into amber bottle or just pull the stopper out and
pour whatever you want into it and reseal. As long as you don't
touch the lip of the bottle with something non-sterile it will
still be sterile.
Preparation
Read directions
all the way through, first.
'Easy'
Kit Directions
1. Add 2000mg
of your favorite 'hormone' to vial '1' and let set overnight .
(see V1 for an alternative)
2. Place vial
'1' into some water which has been boiled or directly onto a heating
element at its lowest setting unit the crystals dissolve and any
little bits of 'pill' filler are dissolved. When using a heating
element you should be able to hold the vial at a point halfway
down the vial. If you can't hold the vial, the heat is too high!
If the solution turns black it is too hot. Reddish brown is ok
as that is the color of the glue.
3. Swirl until
the color is even which should be gold/orange/caramel for the
most popularly used 2000mg powders. The solution should not be
black/red if your 'pills' are new and you have keep the heat within
the parameters explained in step 2.
4. Replace
stopper and let set 1-2 hours to allow the fillers and glue to
settle.
(Next Day)
AS THE BOTTLE
SITS RIGHT NOW YOU HAVE 100% YIELD OF 75MG/ML. Well, actually you
have 2000mg of 'hormone/pro-hormone' suspended in about 5ml of solution!
Nevertheless, DO NOT inject this or it will burn like hell without
the addition of the oil.
5. Pour vial
'2' liquid contents into bottle number 1. The fillers and glues
will sit on the bottom of vial '1'. Bottle 2 is sterile with sterile
oil.
6. Swirl until
the colors are even.
7. For better
sterility put into a 250 degree oven for 20 minutes.
8. Use on
research or farm animals, or discard after you have successfully
completed this experiment.
'Sterile'
Directions
1. Add your
2000mg of hormone to vial '1'. If you have a Double kit you
add 4000. (See V1 for an alternative)
2. Boil some
water or turn on an electric element to its lowest setting.
3. Place vial
'1' into the water or directly onto a heating element at its lowest
setting until the crystals dissolve and any little bits of 'pill'
filler are dissolved. When using a heating element you should
be able to hold the vial. If you can't hold the vial, the heat
is too high.
4. Swirl until
the color is even which should be gold/orange/caramel for the
most commonly used 2000mg of 'hormone/pro-hormone' powders.
5. Let set
1 hour or until cooled to room temp with the stopper in.
AS THE BOTTLE
SITS RIGHT NOW YOU HAVE 100% YIELD OF 75MG/ML. Well, actually you
have 2000mg of your 'hormone/pro-hormone' in about 5ml of solution!
YOUR PATIENCE AND ABILITY TO FOLLOW THE FILTERING DIRECTIONS WILL
DETERMINE YOUR FINAL TOTAL ML. FURTHERMORE, IF YOU HAVE ANY PROBLEMS
YOU NEED TO NOTIFY ME! Even if you have done something wrong and
the filters clog you STILL have 75mg/ml and we can save it.
6. Add vial
'2' to vial '1' and swirl until the colors are even. You will
see a white cloudy precipitate and the glue dropping out and the
solution becoming cloudy. This precipitate is a necessary evil
and IS NOT your 'hormone'. Due to the glue, an excess of one of
the chemicals is used to make the heating steps workable or the
hormone and fillers would stick to the bottom in the clump. When
the second vial is added, this extra drops out.
7. Let set
overnight to allow the pot to settle or proceed to 8 if you are
in a hurry. (See V3) You will have a layer of yellow binder in
the bottom and then a small layer of white crystals and then the
solution.
Note:
You can skip steps 8-16 if your 'hormone' has no fillers/binders/or
glue in it or if there is no cloudiness. If it were me, I would
draw off all the clear and sterile filter and then go back to step
8-16 to 'squeeze' the rest of the 'hormone' out of the filler/glue
mess.
8. Insert
a funnel into an empty clear vial and insert the coffee filter.
If you don't have a funnel to fit into a vial, you can secure
the coffee filter over any glass container with a rubber band.
(See V2)
9. Pour the
liquid solution from vial 1 into the coffee filter leaving as
much filler behind as possible. Turn the vial on its side.
10. Allow
all of that 'pour' to drain through the filter or until the drips
stop. When that is done draining add all the rest of the junk
left in the bottle to the coffee filter.
11. You may
want to let is set overnight as the draining will be slow due
to the filler.
12. Close
up the coffee filter and wring it from the edges inward to where
the 'solution' was.
13. Begin
twisting from the open edges of the filter. A 'Balloon' will develop.
14. Press
gently onto the balloon while holding onto the twisted part of
the filter.
15. Twist
the filter evermore into the balloon area, but be careful not
to tear the filter. Wring it out like a miniature towel. This
procedure lets you get all but about 1ml out of the coffee filter.
Note:
In case you think you have doubts about what the brown residue is
in the coffee filter, you can test it! Scrape the residue into a
small clear glass vial or container. Add 5-10ml of methanol or acetone.
The brown stuff will begin to turn white (filler) and the liquid
you added will take on a tan tint. The white will stay on the bottom
and will not go into solution. Your liquid will not turn yellow
because there are no hormones in the residue. (No applause, please)
Discard the test product
16. (Pre-filter
and old style filter insertion. If you have the GMX or GDF filters
you can go directly to step 17. A. Draw the coffee filtered solution
into the syringe. B. Place a white pre-filter onto the tip of
the syringe. C. Push the liquid through into vial #2. D. After
the solution is all into vial 2 and pre-filtered remove the pre-filter.
E. Draw 20ml into the syringe. F. Go to step 20.)
17. Draw 20ml
oil out of the container holding your caramel colored, coffee
filtered solution.
18. Turn the
syringe upside down.
19. Remove
the needle.
20. Open the
sterile filter package, but leave the filter in the plastic!
21. Holding
the filter through the plastic, place the sterile syringe filter
onto the syringe. (See V2 for an alternative)
22. Remove
the stopper from vial 3 and place it into the now empty sterile
syringe container. (See V4 for an alternative for which you don't
need to remove the stopper.)
23. Place
the syringe filter immediately onto the mouth of the sterile vial
'3'.
24. Push all
the contents of the syringe into the vial by grasping the syringe
with 2 hands. Using your index fingers or thumbs push down on
the plunger while continuing to hold onto the syringe with 2 hands.
DO NOT EXERT EXTREME PRESSURE DOWNWARD ONTO THE SYRINGE FILTERS!
If you move the wrong way the vial will go shooting across the
table and there goes your experiment. Also, if you push too hard
the flow through the syringe filter will slow. It should take
5-6 second per ml of oil flowing through the syringe filter.
If you have
any questions on this step you need to email me. With the new filters
and procedure there is no longer any excuse for clogged filters.
These filters will not clog even if you do 100ml!
25. When the
oil is out of the syringe you will need to reload. Grasping the
syringe filter by its sides, unscrew the syringe and LEAVE THE
SYRINGE FILTER ON THE VIAL! Reload the syringe as in steps:16-19
26. When the
oil is out of the syringe there is still some oil left in the
filter and you want to salvage that. Remove the syringe filter
from the syringe by holding onto the sides of the syringe filter
and unscrewing the syringe. LEAVE THE SYRINGE FILTER ON THE VIAL.
Draw air into the syringe. Put the syringe filter back on. Blow
the air through the filter. Do this 1-2 times.
27. Replace
the rubber stopper when all the oil has been pushed through the
syringe.
28. Use for
animals, research, or discard. This practice in crystalline solutions
and sterility is not intended for human use.
Variations
Variation 1:
Put pellets
into vial one and then place into/onto your heat source until
pellets are dissolved. Should take 1/2 hour.
Variation 2:
1.Place the
18 gauge needle onto the 20ml syringe.
2.Draw 20ml
of oil out of the container holding your caramel colored solution.
3.Turn the
syringe upside down.
4.Remove the
needle.
5.Open the
sterile filter package, but leave the filter in the plastic!
6.Holding
the filter through the plastic, place the sterile syringe filter
onto the syringe.
7.Place the
second sterile needle onto the syringe filter.
8.Place the
needle through the stopper of the sterile vial, '3'.
9.Push all
the contents of the syringe into the vial by grasping the syringe
with 2 hands. Using your index fingers or thumbs push down on
the plunger while continuing to hold onto the syringe with 2 hands.
DO NOT EXERT EXTREME PRESSURE DOWNWARD ONTO THE SYRINGE FILTERS!
If you move the wrong way the vial will go shooting across the
table and there goes your experiment. Also, if you push too hard
the flow through the syringe filter will slow. It should take
5-6 second per ml of oil flowing through the syringe filter.
Variation 3:
If all the
binders settle to the bottom you can proceed to step 17. I would
then Pour the remaining binder mix into the coffee filter set-up
and let it drain out. You should be able to get 5 more ml out
of that.
Variation 4:
Tear out
the center seal of the sterile vial. Insert a needle only into
the vial to relieve pressure. Place a needle onto the syringe
filter and go to step 23.
Copyright
1999 Jason Meuller and Anabolic Extreme. This material may not be
copied, reproduced, or transmitted without the express written permission
of the copyright owners.
BACK
TO CURRENT ISSUE
|